Product Safety Test Equipment Calibration Services

Send your product safety test equipment to ED&D for calibration, inspection, recertification, and repair support. Our in-house laboratory serves manufacturers, independent laboratories, NRTLs, certification bodies, and engineering teams that need dependable measurements and documentation for audit-ready safety testing programs. We service applicable ED&D equipment and equipment from other manufacturers.

ISO/IEC 17025:2017 ANAB Accredited Certificate AC-1425 Measurement Traceability ED&D & Other Brands Calibration & Repair Support

Accredited Calibration
ISO/IEC 17025 accredited calibration is available for measurements covered by ED&D’s current ANAB Scope of Accreditation.

Safety Equipment Expertise
Work with a laboratory that also designs and manufactures product safety test equipment.

One Service Contact
Request calibration, incoming evaluation, repair support, documentation, and return service through one RMA process.

Request a Calibration Quote & RMA Call (919) 469-9434

Include the manufacturer, model, serial number, measurement range, required parameters, requested certificate type, and applicable standard or laboratory procedure.

Calibration for Product Safety and Compliance Test Equipment

Product safety laboratories depend on test instruments, fixtures, probes, gauges, and mechanical devices that produce repeatable results. ED&D provides calibration and service support for equipment used in electrical safety, accessibility, ingress protection, mechanical impact, flammability, dimensional verification, force, temperature, and related compliance testing.

ED&D can evaluate many instruments made by ED&D as well as competitive and specialized devices. Service acceptance, calibration method, measurement points, documentation, and accredited status depend on the exact equipment, its condition, the requested parameters, and ED&D’s current accredited scope.

For Existing Lab Equipment
Arrange periodic recalibration, recertification, evaluation, or repair for applicable equipment already in service.

For New ED&D Equipment
Ask which calibration and documentation package best fits your standard, quality system, and audit requirements.

For Other Manufacturers’ Equipment
Send the make, model, range, specifications, and required calibration points for a capability review.

Safety Test Equipment We Can Evaluate for Calibration

The categories below reflect the broad range of product safety equipment ED&D supports. Some systems contain multiple devices or measurement functions that may require separate calibration, inspection, verification, or service steps.

Scope note: inclusion in this list does not mean every model, function, range, or measurement is covered by ISO/IEC 17025 accreditation. ED&D will confirm capability and accredited status for the exact item and requested parameters before service.

Electrical Safety & Electrical Measurement

Ingress Protection & IP Test Equipment

Impact, Mechanical Abuse & Flexing

Force, Torque, Stability & Sharpness

Medical, Environmental & Specialty Equipment

  • Medical-device and medical-bed safety test equipment
  • Environmental, corrosion, toy, and X-radiation test equipment
  • Entrapment, loading, and dimensional assessment tools
  • Specialized and custom product safety test equipment
  • Other laboratory instruments related to safety compliance testing

Not Sure Where Your Equipment Fits?

Send ED&D the manufacturer, model, serial number, photographs, operating manual or specification, measurement range, and the calibration points your quality system requires.

You can also review all ED&D product categories before submitting your equipment details.

Request a Capability Review

ISO/IEC 17025 Calibration, Traceability & Documentation

Educated Design & Development, Inc. is accredited by ANAB to ISO/IEC 17025:2017 under Certificate AC-1425. The current accredited scope includes capabilities in Electrical & DC / Low Frequency, Length – Dimensional Metrology, Mass and Mass Related, Thermodynamic, and Time and Frequency calibration.

Accredited work is performed only for measurements and ranges listed on the current Scope of Accreditation. Where applicable, calibration records provide measurement traceability to recognized standards, including NIST. ED&D will identify whether the requested service is accredited, traceable non-accredited, inspection, verification, or repair before the work is authorized.

Current Scope Review
Calibration capability is matched to the requested function, range, method, and measurement points.

Certificate Options
Ask about accredited certificates, recorded data, and measurement-uncertainty information for applicable services.

Audit Support
Clear equipment identification, service results, traceability, and status help support laboratory quality records.

View the Current ANAB Certificate & Scope

The ANAB document is the controlling source for current accredited capabilities, ranges, and uncertainties.

How to Send Equipment to ED&D for Calibration

1. Request a Quote & RMA
Contact ED&D before shipping. A client support specialist will review the request and issue return instructions.

2. Define the Requirement
Provide make, model, serial number, ranges, required points, certificate needs, due date, and applicable procedure or standard.

3. Ship the Complete System
Follow the RMA instructions and include required probes, fixtures, cables, adapters, power supplies, and accessories.

4. Incoming Evaluation
ED&D confirms equipment condition, requested service, capability, scope status, and any issues that affect calibration.

5. Calibration & Documentation
Authorized work is completed and the applicable certificate, results, and service records are prepared.

6. Return to Service
Equipment and documentation are returned for use in your laboratory. Calibration-due notifications are available.

Before shipping: do not send equipment without an RMA or service instructions. If the equipment has been exposed to hazardous, biological, chemical, or radioactive materials, disclose that information and provide required decontamination documentation before shipment.

Inspection, Repair, Recalibration & Recertification

Calibration can reveal damage, wear, drift, missing components, or operating problems that affect a device’s ability to meet the requested requirement. ED&D can evaluate applicable equipment for repair or adjustment and then recalibrate or recertify it when the required work can be completed.

Because ED&D manufactures product safety test equipment, the service team can also help identify application, setup, accessory, and equipment-selection issues that may affect repeatability or audit readiness.

Send complete information: describe the symptom, include previous service findings when available, and identify any upcoming audit, certification, or production deadline. Repair availability depends on the equipment, parts, condition, and technical feasibility.

Request Calibration or Repair Service Call (919) 469-9434

ED&D is located at 2420 Reliance Ave., Suite 100, Apex, NC 27539 USA.

Calibration Services Frequently Asked Questions

Does ED&D calibrate safety test equipment made by other manufacturers?

Yes. ED&D can evaluate many competitive and specialized instruments for calibration, inspection, or repair. Acceptance depends on the exact model, requested parameters, available methods and standards, equipment condition, and current laboratory capability. Send the make, model, serial number, range, specifications, and required calibration points for review.

Is every calibration performed under ED&D’s ISO/IEC 17025 accreditation?

No. Accredited calibration applies only to measurements, methods, and ranges covered by ED&D’s current ANAB Scope of Accreditation. ED&D will confirm whether requested work is accredited, traceable non-accredited, inspection, verification, or another service type before authorization.

What information should I provide for a calibration quote?

Provide the manufacturer, model, serial number, measurement range, required calibration points, applicable standard or laboratory procedure, requested certificate type, data and uncertainty requirements, current condition, accessories included, quantity, and required return date.

Can ED&D calibrate IP test equipment and accessibility probes?

ED&D can evaluate accessibility probes, dimensional tools, drip boxes, spray systems, nozzles, jet systems, flow and pressure instruments, timers, turntables, dust-test equipment, and related IP test components. The service method and accredited status depend on the exact component and requested parameter.

Can ED&D service impact hammers and other mechanical safety equipment?

ED&D can review spring impact hammers, pendulum equipment, impact bodies, force and torque instruments, masses, mechanical-abuse fixtures, flexing equipment, and related devices. Provide the required energy, mass, force, dimensional, timing, or other measurement requirements with the quote request.

Does ED&D provide repair and recertification?

ED&D provides evaluation, repair, adjustment, recalibration, and recertification support for applicable equipment. Availability depends on the device, its condition, parts availability, and technical feasibility.

How do I get an RMA?

Use the ED&D contact form or call (919) 469-9434 before shipping. Provide the equipment details and requested service so the team can review capability and send the correct return instructions.

Request a Calibration Quote

Tell ED&D what equipment you have, what measurements or verification points you need, and what documentation your quality system or audit requires.